Influence of Commonly Used Endodontic Irrigants on the Setting Time and Metal Composition of Various Base Endodontic Sealers

Author name : KUMAR CHANDAN SRIVASTAVA
Publication Date : 2021-12-22
Journal Name : Ploymers

Abstract

The present study aimed to evaluate if commonly used endodontic irrigants such as 3% sodium hypochlorite (NaOCl, Prime Dental, Thane, India), 2% chlorhexidine (CHX, Sigma-Aldrich Co., St. Louis, MO, USA), and 17% ethylenediaminetetraacetic acid (EDTA, Meta-Biomed Co. Ltd., Cheongju-si, South Korea) influenced the setting time and metal composition of different base endodontic sealers on exposure. AH Plus (Dentsply De Trey GmbH, Konstanz, Germany), Sealapex (SybronEndo, Orange, CA, USA), mineral trioxide aggregate (MTA) Fillapex (Angelus Soluções Odontológicas, Londrina, Brazil), and Tubli-Seal (Kerr Dental, Orange, CA, USA) were selected as the different base representatives of endodontic sealers. These sealers were exposed to 3% NaOCl, 2% CHX, and 17% EDTA, and the individual setting time of the sealers was analyzed. The samples were analyzed for heavy metal elements such as chromium (Cr), nickel (Ni), cobalt (Co), cadmium (Cd), arsenic (As), mercury (Hg), lead (Pb), and beryllium (Be) by using inductively coupled plasma mass spectrometry (ICP-MS) analysis. For statistical analysis, one-way ANOVA and post hoc Tukey's tests were used. All selected sealers showed variation in setting time post-exposure to different irrigants. MTA Fillapex had the shortest mean setting time (215.7 min, post-exposure at 187.3 min) (p < 0.05). Mean setting time was also affected for AH Plus (479.6 min, post-exposure at 423.9 min) (p < 0.05) and Tubli-Seal (514.7 min, post-exposure at 465.2 min) (p < 0.05). Sealapex showed the maximum reduction of setting time (864.8 min, post-exposure at 673.4 min) (p < 0.05). All tested sealers showed heavy metals (Cr, Ni, Co, Cd, As, Hg, and Pb) in their composition, and the quantities were influenced by interaction with different irrigants. The heavy metal Be was not seen in any of the samples. Sealapex showed the longest setting time in comparison to other test sealers. Heavy metals were most present in Sealapex, followed by AH Plus, Tubli-Seal, and MTA Fillapex. MTA Fillapex was seen to have the shortest setting time, and heavy metal composition was least affected on interaction with different commonly used endodontic irrigants. Further, this study provides significant insight into the influence of different endodontic irrigants on interaction with different base endodontic sealers, which has not been reported previously, and future studies should emphasize endodontic irrigant-sealer interactions and their possible effects in the long run.

Keywords

endodontics; heavy metals; root canal filling materials; root canal irrigants

Publication Link

https://pubmed.ncbi.nlm.nih.gov/35012047/

Block_researches_list_suggestions

Suggestions to read

HIDS-IoMT: A Deep Learning-Based Intelligent Intrusion Detection System for the Internet of Medical Things
Ahlem . Harchy Ep Berguiga
Generalized first approximation Matsumoto metric
AMR SOLIMAN MAHMOUD HASSAN
Structure–Performance Relationship of Novel Azo-Salicylaldehyde Disperse Dyes: Dyeing Optimization and Theoretical Insights
EBTSAM KHALEFAH H ALENEZY
“Synthesis and Characterization of SnO₂/α-Fe₂O₃, In₂O₃/α-Fe₂O₃, and ZnO/α-Fe₂O₃ Thin Films: Photocatalytic and Antibacterial Applications”
Asma Arfaoui
Contact