Abstract

This paper introduces a new method for real-time high-density impulsive noise elimination applied to medical images. A double process aimed at the enhancement of local data composed of Nested Filtering followed by a Morphological Operation (NFMO) is proposed. The major problem with heavily noisy images is the lack of color information around corrupted pixels. We show that the classic replacement techniques all come up against this problem, resulting in average restoration quality. We only focus on the corrupt pixel replacement phase. For the detection itself, we use the Modified Laplacian Vector Median Filter (MLVMF). To perform pixel replacement, two-window nested filtering is suggested. All noise pixels in the neighborhood scanned by the first window are investigated using the second window. This investigation phase increases the amount of useful information within the first window. The remaining useful information that the second window failed to produce in the case of a very strong connex noise concentration is then estimated using a morphological operation of dilatation. To validate the proposed method, NFMO is first evaluated on the standard image Lena with a range of 10% to 90% impulsive noise. Using the Peak Signal-to-Noise Ratio metric (PSNR), the image denoising quality obtained is compared to the performance of a wide variety of existing approaches. Several noisy medical images are subjected to a second test. In this test, the computation time and image-restoring quality of NFMO are assessed using the PSNR and the Normalized Color Difference (NCD) criteria. Finally, an optimized design for a field-programmable gate array (FPGA) is suggested to implement the proposed method for real-time processing. The proposed solution performs excellent quality restoration for images with high-density impulsive noise. When the proposed NFMO is used on the standard Lena image with 90% impulsive noise, the PSNR reaches 29.99 dB. Under the same noise conditions, NFMO completely restores medical images in an average time of 23 milliseconds with an average PSNR of 31.62 dB and an average NCD of 0.10.

Keywords

medical images; high-density impulsive noise; image processing; high-level synthesis; FPGA

Publication Link

https://doi.org/10.3390/diagnostics13101709

Block_researches_list_suggestions

Suggestions to read

HIDS-IoMT: A Deep Learning-Based Intelligent Intrusion Detection System for the Internet of Medical Things
Ahlem . Harchy Ep Berguiga
Generalized first approximation Matsumoto metric
AMR SOLIMAN MAHMOUD HASSAN
Structure–Performance Relationship of Novel Azo-Salicylaldehyde Disperse Dyes: Dyeing Optimization and Theoretical Insights
EBTSAM KHALEFAH H ALENEZY
“Synthesis and Characterization of SnO₂/α-Fe₂O₃, In₂O₃/α-Fe₂O₃, and ZnO/α-Fe₂O₃ Thin Films: Photocatalytic and Antibacterial Applications”
Asma Arfaoui
تواصل معنا