تجاوز إلى المحتوى الرئيسي

Monomer Elution from Three Resin Composites at Two Different Time Interval Using High Performance Liquid Chromatography?An In-Vitro Study

Author name : KUMAR CHANDAN SRIVASTAVA
Publication Date : 2021-12-15
Journal Name : Ploymers

Abstract

Esthetics, improved colour stability and ease of contour have made photo-activated resin based restorative materials being widely used in routine dental clinical practice. Perhaps improper and inadequate polymerization of resin based composite material might lead to elution of monomer. Thus, the aim of the current study was to quantify the monomer elution from three resin composites. The intended analysis was made using high performance liquid chromatography (HPLC) at two different time periods. Three different materials that were investigated in the current study included Swiss Tech resin composite (Group A), Ceram X (Group B) and Beautifil Injectable composite (Group C). Ten cylindrical samples were fabricated in each study group. In 75% wt of ethanol, the samples were ingressed immediately and stored at room temperature. A 0.5 mL of the samples was assessed at pre-defined time intervals at 24 h and 7th day. Later, assessment of the samples was performed with HPLC and the data was analyzed using statistical test. Bisphenol A-glycidyl methacrylate (Bis-GMA), Triethylene glycol dimethacrylate (TEGDMA), 2-hydroxyethyl methacrylate (HEMA) and Urethane dimethacrylate (UDMA) were quantified in the samples. When analyzing the release monomer, it was found that at the end of 24 h Bis-GMA was eluted more in the injectable resin composite whereas, TEGDMA was eluted from Swiss Tech and Ceram X resin composites. At the end of the 7th day it was evident that Bis-GMA was eluted maximum in all the three resin composites. Thus, monomer release was found to be evident among all three resin composites and it is of utmost important to be assessed in routine clinical practice.

Keywords

Bis-GMA; bulk fill composites; conventional resin composites; dental restorations; high performance liquid chromatography; monomer release; residual monomer

Publication Link

https://pubmed.ncbi.nlm.nih.gov/34960944/

Block_researches_list_suggestions

Suggestions to read

HIDS-IoMT: A Deep Learning-Based Intelligent Intrusion Detection System for the Internet of Medical Things
Ahlem . Harchy Ep Berguiga
“Synthesis and Characterization study of SnO2/α-Fe2O3, In2O3/α-Fe2O3 and ZnO/α-Fe2O3 thin films and its application as transparent conducting electrode in silicon heterojunction solar cell”
Asma Arfaoui
Frequency and voltage dependent of electrical and dielectric properties of 14 nm Fully Depleted Silicon-On-Insulator (FD-SOI)
MOHAMMED OMAR MOHAMMEDAHMED IBRAHIM
Biosynthesis of Zn-nano complex using Olive seeds for Antimicrobial Regulation of Nanostructured Materials
MERVAT RAGAB ATTA MOHAMED
تواصل معنا